+1 727-586-6288 RFQ

Common Mode Chokes

Distributed by ZD Integrated Circuits with counterfeit-avoidance inspection on every lot. Hard-to-find, obsolete, and excess common mode chokes sourced worldwide.

Passive components (resistors, capacitors, inductors and their networks) set the values every active circuit depends on. Long production runs mean many legacy and military-grade values outlive their original suppliers. That is where an independent distributor with a deep catalog earns its place.

131catalog parts
5in ZDI stock
8major manufacturers
8+package styles
Common Mode Choke — 0805 (2012 metric) chip drawing
0805 (2012 metric) chip

Top manufacturers in this category

Packages in this category

Common Mode Chokes at a glance

In-stock & featured parts

744083330JWürth Elektronik4-Line Common Mode Choke, 33 µH, 200 mA, 0805 · 0805
In ZDI stock
DLF2500Coilcraft2-line data-line common-mode filter, 2.5 A · Unknown
In ZDI stock
ELF18D221FPanasonicCommon mode choke coil, 2.2 mH, 1 A, for AC power line filtering · Vertical through-hole
In ZDI stock
EXC-ML32A680UPanasonicCommon Mode Choke, 68 Ohm @ 100MHz, 4A, 1210 SMD · 1210
In ZDI stock
ZJYS51R5-2PTDK2-line SMD common mode filter for signal lines, 1000Ω @ 100MHz typ · SMD
In ZDI stock
ZJYS51R5-2PLTTDK2-line common mode filter, 1000Ω @ 100MHz, 0.5A, SMD · SMD
Available
ZJYS51R5-4PTDK4-line SMD common mode filter for signal lines · SMD
Available
ZJYS51R5-2PTTDK2-line common mode filter, 500 mA, 50 V, SMD · SMD
Available
ZJYS81R5-2PL51-GTDKCommon mode filter for high-speed differential signal lines · SMD
Available
2A30-EPO-B82731M213EPCOS (TDK)Current-compensated power line choke, 2 A, 30 mH
Available
MU2-DLW31SN222SQ2LMurata ElectronicsCommon mode choke coil, 2200Ω @ 100MHz, 50mA, 1206 · 1206 (3216 metric)
Available
T1-MU2-DLW31SN900SQ2LMurata ElectronicsCommon mode choke, 90Ω @100MHz, 2 lines, 150mA, 1206 SMD · 1206
Available
L-TD4-ACT45B-510-2P-TTDKCommon-mode choke, 2-line, 51uH, for CAN-BUS, SMD · 1812
Available
MUR-DLP11SA900HL2LMurata ElectronicsCommon mode choke coil, 90 Ω @ 100 MHz, 150 mA, 2 lines · 0504 (1.25 x 1.00 mm)
Available
DLP0NSN900HL2LMurata ElectronicsCommon mode choke coil, 90Ω @ 100MHz, 100mA, 4-terminal SMD · 0302 (0.85 x 0.65 mm)
Available
B82790-C0475-N340TDK2-line SMD common-mode choke, 4.7 mH, 0.5 A · SMD
Available
DR331-475BEBournsCommon mode choke, 4.7 mH, SMD · SMD
Available
ACM2012D-900-2P-T00TDK2-line common mode filter, 90Ω @ 100 MHz, 0.3 A, 0805 · 0805 (2012 metric)
Available
ACM2012-121-2P-T000TDK2 Line Common Mode Choke 120 Ohms @ 100 MHz 370 mA 300 mOhm DCR 0805 · 0805 (2012 Metric)
Available
ACM2012H-900-2P-T00TDKCommon mode filter, 90Ω @ 100MHz, 2 lines, 300mA, 0805 metric · 0805 (2012 metric)
Available
ACM12V-701-2PL-TL00TDKCommon mode filter, 2-line, for automotive power lines · SMD
Available
DLP31SN551SL2Murata Electronics2 Line Common Mode Choke 550 Ohms @ 100 MHz 100mA DCR 2.4 Ohm · 1206 (3216 Metric)
Available
ZJYS51R5-4PT-01TDK4-line common mode filter, 200mA, 50V, SMD, for signal lines · SMD
Available
ACM2012-900-2P-TTDKCommon mode filter, 90 Ω @ 100 MHz, 300 mA, 2-line · 0805 (2012 Metric)
Available

Green = physically in ZDI stock today. All 131 common mode chokes are searchable by part number.

Common Mode Chokes buyer’s guide

Key specifications

Value and tolerance
The nominal resistance, capacitance or inductance, and how far a part may deviate from it (for example ±1%, ±5%).
Temperature coefficient
How much the value drifts with temperature, given in ppm/°C for resistors or as a dielectric class such as C0G or X7R for capacitors.
Voltage and power rating
The maximum working voltage, and the power a part can dissipate at its rated temperature.
Case size
The footprint, such as 0402, 0603, 0805, 1206 or 2512 for chips, or axial and radial for leaded parts.

Standards

  • AEC-Q200 (automotive passive qualification)
  • MIL-PRF military specifications for established-reliability parts
  • RoHS and REACH material compliance

Typical applications

  • Signal conditioning and filtering
  • Power supply decoupling and bulk storage
  • Precision measurement and reference circuits
  • Legacy and military board repair

How ZDI inspects common mode chokes

  • Lot-level visual inspection under magnification: markings, date and lot codes, body finish, lead or termination condition
  • Packaging and labels checked against the maker's format; moisture-sensitive parts kept in MSL control (J-STD-033)
  • Counterfeit-avoidance steps based on AS6081 and AS5553, with X-ray and further tests escalated by risk
  • Inspection photos and an EQP report available to customers in My ZDI

Our inspection process follows AS6081 counterfeit-avoidance practice. See Quality & AS6081.

Frequently asked questions

Can a different maker's part replace an obsolete passive?

Often yes, when the value, tolerance, temperature coefficient, rating and case size all match. We'll confirm a cross and quote both options.

Do you supply cut tape and partial reels?

Yes. Tell us the quantity and packaging you need on the RFQ.

Browse all 131 common mode chokes

0603USB-951MLC29F0318-1SR29F0330-2SR-102A30-EPO-B82731M2137102-RC744083330J744221744235900744242101744272392744692400374482111074482410174482560338107-RCACM0706-102-2P-TACM1211-102-2PL-TL01ACM1211-701-2PL-TLACM12V-701-2PL-TL00ACM2012-121-2P-T000ACM2012-900-2PACM2012-900-2P-TACM2012D-900-2P-T00ACM2012H-900-2P-TACM2012H-900-2P-T00ACM2520-102-2PACM2520U-201-2PACM3225-102-2P-TACM4532-102-3PACM4532-801-2P-TACT45B-220-2P-TLACT45B-510-2PACT45B-510-2P-003B82720B82720-K2102-N40B82720K2202NB82720K2301N042B82720S2202N040B82720S2202N40B82722-J2302-N1B82723-A2402-N1B82724-J2402-N1B82790-C0225B82790-C0225-N265B82790-C0475-N340B82790-C474-N215B82790-S0513-N201B82791-G14-A16B82791-H2351-N1-200B82792-C0685-N365B82793C0105N265CM2545X171R-10CM2722R151R-10CM3032V201R-10CM3322U610R-10CM3421Y600R-10CM5441Z161B-10CM6460R-504DLF2500DLP0NSN900HL2LDLP11SN331HL2LDLP11SN900HL2LDLP2ADN241HL4LDLP31SN121ML2LDLP31SN121SL2LDLP31SN221ML2LDLP31SN221SL2DLP31SN551ML2LDLP31SN551SL2DLP31SN551SL2LDLW21HN900SQ2DLW21HN900SQ2LDLW21SN181SQ2LDLW21SN371SQ2LDLW21SN670SQ2LDLW21SN900SQ2DLW21SN900SQ2LDLW31SH222SQ2LDLW31SN102SQ2LDLW31SN161SQ2LDLW31SN222SQ2DLW31SN900SQ2LDLW5BSN191SQ2DLW5BSN191SQ2LDLW5BSN302SQ2LDLW5BTN102DLW5BTN142SQ2LDLW5BTN501SQ2LDR221-333AEDR331-475BEELF18D221FEXC24CP121CEXC-CL3225U1,2AEXC-ML32A680UL-TD4-ACT45B-510-2P-TMU2-DLW31SN222SQ2LMUR-DLP11SA900HL2LP0351NLTP0353NLP0353NLTP0354NLTP0355TP0420NLP0422P0422NLTP0422TP0429NLTP0469NLP0473NLTPA0491NLTPA1134NLTPA1137NLPLA10AN1030R7R2BPLA10AN5521R0R2BPLA10AS5521RORPLM250S50T1M00-02PLT09HN2003R0P1BPM3700-50RN202-1/02T1-MU2-DLW31SN900SQ2LZJYS51R5-2PZJYS51R5-2PLTZJYS51R5-2PLT-01ZJYS51R5-2PTZJYS51R5-2PT-01ZJYS51R5-4PZJYS51R5-4PTZJYS51R5-4PT-01ZJYS51R5-M4PAT-01ZJYS81R5-2PL51-GZJYS81R5-2PL-51T-G01

Need a part in this category?

Obsolete and allocated common mode chokes — sourced worldwide and inspected in-house under our quality system, built on ISO 9001:2015 and AS6081.